48V vs 120V lighting: which should a new home use?
Short answerMost new homes use both. Choose 48V DC for downlights and other built-in lighting when you want scenes, deep dimming and the equipment in one place, and can plan a rack before the walls close. Keep 120V AC for outlets, appliances, standard lamps and small projects. An electrician still wires the 120V side.
48V DC vs 120V AC lighting, side by side
LEDs run on low-voltage DC. The real choice is where 120V AC is converted: once at a rack, or at every light.
| Decision | 48V DC from a rack | 120V AC to each light |
|---|---|---|
| AC to DC conversion | In the rack power supplies | In a driver in or near each light |
| Power per circuit | A Class 2 source stops at 100 VA, so there are many small runs | Set by breaker and cable, so fewer, larger circuits |
| Cable length | Part of the design, because current is higher | Less sensitive, because current is lower |
| Dimming | By the drivers in the rack | Often by a wall dimmer, which must suit each driver |
| Regrouping lights | In software, if each fixture has its own address | Usually rewiring, or added controls |
| Driver service | At the rack | At the fixture, often in a finished ceiling |
| One failed part | A supply or processor can affect several lights | A driver affects one light, a breaker one circuit |
| Space | Rack, airflow and service access | Wall boxes in each room |
| Standard screw-in lamps | No | Yes |
For how one 48V system is built, from keypad to fixture, see how 48V lighting works.
What runs where, and what still needs 120V
Colorbeam is built on 48V DC low-voltage infrastructure, powering fixtures over Cat6 network wire. Tape light runs at 24V.
| Load | Usual supply | Plan for |
|---|---|---|
| Downlights and other built-in 48V fixtures | 48V DC | Cable route to the rack, address, zone |
| Tape light | 24V in a Colorbeam system | More current for the same watts, so wire size and length |
| Chandeliers, table lamps, screw-in lamps | 120V AC | A switched circuit or outlet, and how it joins the scenes |
| Outlets, appliances, hardwired smoke alarms | 120V AC, or 240V for some appliances | Ordinary branch circuits |
| The lighting rack | 120V AC in, low voltage out | Its own circuits, airflow, service access |
Check wet areas early. In US code the lighting limit drops to 30V DC where wet contact is likely, so 48V does not suit every shower, pool or outdoor spot.
Voltage, current and cable length
Watts equal volts times amps, so at the same watts 48V needs 2.5 times the current of 120V. Wire loses voltage equal to current times resistance.
For the same wire and load, the share lost falls with the square of the supply voltage. At 48V it is about 6 times the share at 120V, a quarter of the share at 24V and one sixteenth of the share at 12V.
| 20 W over 30 m (98 ft) of thin wire | Current | Voltage lost | Share lost |
|---|---|---|---|
| 120V | 0.17 A | 0.7V | 0.6% |
| 48V | 0.42 A | 1.8V | 3.8% |
| 24V | 0.83 A | 3.7V | 15% |
| 12V | 1.67 A | 7.3V | 61%: not workable |
Simple arithmetic, not a wiring specification: one 23 AWG conductor out and one back, at the 0.0732 ohm per meter assumed for Category 6 cable. House wiring for 120V is thicker. Real designs may share current across more conductors, so follow the maker's limits.
How current and wire layout shape magnetic fields is covered under why 48V is not the same as 12V.
Drivers, heat, dimming and EMF
- Heat. A rack gathers conversion heat in one room, so plan airflow there. At 120V, each driver gives off its heat at the fixture.
- Service. In a stress test of indoor LED luminaires for the US Department of Energy, failures typically occurred in the driver circuit. Very few were in the LEDs. Ask who can reach the driver, and how. Colorbeam's rackmount units are fanless and fit a standard AV rack.
- Dimming and flicker. DC is not flicker free by itself. The Department of Energy explains that the driver, and how it answers a dimmer, decides whether LEDs flicker. Colorbeam dims smoothly to 0.1%. More on flicker-free dimming.
- EMF. Colorbeam's low-voltage architecture mitigates upwards of 90% of EMFs produced by conventional 120V lighting, with the lowest measurable EMF readings in the architectural lighting industry. The rack still has a 120V feed, so place it with the low EMF lighting plan.
Codes: Class 2, Article 411, Article 725 and Class 4
Low voltage is not outside the code. The class comes from the power source, not from the voltage or the cable.
| US rule (NEC) | What it covers | What it means for 48V lighting |
|---|---|---|
| Chapters 1 to 4 | Ordinary power wiring | Apply to the 120V side of Class 2 supplies. In the 2020 edition, overcurrent protection there is 20 A at most |
| Article 411 | Low-voltage lighting. The 2017 text covers up to 30V AC or 60V DC, or 15V AC and 30V DC where wet contact is likely | 48V DC is within the dry limit. Use a listed system or listed parts. Some guides still quote 30V only |
| Article 725, Class 2 | Power-limited circuits, commonly up to 60V and 100 VA | A listed, marked source, listed cable in buildings, and separation from power wiring |
| Article 726, Class 4 | Fault-managed power up to 450V. A paired transmitter and receiver limit energy into a fault | A different system from 48V Class 2. Not permitted in dwellings in the 2023 edition |
The 2026 NEC moved Class 2 power sources to Article 721 and cables to Article 722. States are on different editions, so ask which applies. The NEC also calls for wall-mounted lighting controls in required rooms, so show the keypads to the inspector early.
In Canada, Section 16 of the Canadian Electrical Code covers Class 2 circuits. A guide to the 2018 edition lists 60V DC for dry or damp locations and 30V DC for wet ones, separation from power wiring, and approval for all lighting products. Rules also differ by province.
Everywhere, the licensed electrician and the local authority decide.
Who installs what
- Licensed electrician: rack circuits, 120V lighting, outlets and grounding.
- Integrator or low-voltage installer: CAT6 and tape wiring, rack, addressing and scenes, where licensing allows. Colorbeam wiring is not ordinary Ethernet PoE: see integrators.
- Architect and builder: rack room, vertical routes, ceiling details, and a check before the walls close.
Licensing differs by state and province. Ask the local authority who may run the low-voltage side.
Cost drivers
| Driver | 48V from a rack | 120V to each light |
|---|---|---|
| Equipment | Supplies, decoders, processor and rack, needed even for a few lights | Dimmers or smart switches, and a driver per light |
| Wire | Number of runs and distance to the rack | Power cable, boxes, multi-way switching |
| Labor | Two trades to coordinate, plus programming | Mostly electrician hours |
| Changes | More decisions before rough-in | Regrouping later can mean new wiring |
Backup power and retrofit limits
Backup. Backing up the rack, its processor and the controls can keep the 48V lights available. At 120V, each lighting circuit needs to be on a backed-up panel. Size a battery for the rack's input load, ask which type the supplies accept, and split stairs and halls across supplies.
Retrofit. New cable has to reach the lights, so 48V suits new homes and open ceilings. Where ceilings stay closed, 120V may be the sensible choice, or 48V in the renovated rooms only.
How to choose, and what to ask
- List the lights.Many built-in lights and scenes favor 48V. Mostly decorative lamps favor 120V.
- Find the rack a home.No room with airflow and access favors 120V.
- Check the stage.48V needs routes and zones fixed before rough-in. A lighting design study can set positions and zones.
- Ask the maker.Is each supply listed and marked Class 2? What are the length and load limits? What fails together? Which spares are stocked?
- Ask the electrician and inspector.Which code edition, permits, licenses, cable types and separation apply?
- Ask the installer.Who tests and labels each run and hands over drawings?
Questions and answers
Is 48V lighting better than 120V for a new home?
For built-in lighting with scenes and deep dimming, 48V has real advantages: drivers in one place, addressable fixtures and no 120V lighting cable past the rack. For a few simple lights or standard lamps, 120V is simpler.
Does 48V lighting need an electrician?
Yes, for the 120V circuits that feed the rack. Who may run the low-voltage side depends on the state or province, so ask the local authority.
Is 48V DC lighting always Class 2?
No. The power source sets the class. A 48V supply counts as Class 2 when it is listed and marked that way, commonly within 60V and 100 VA. At 48V, 100 VA is about 2 amps.
How far can you run 48V lighting on CAT6?
It depends on the watts, the wire size and how many conductors share the current. Use the limits for the exact fixture and supply.
Does 48V lighting use less electricity than 120V?
Not because of the voltage alone. A US Department of Energy study of PoE lighting says consolidating AC to DC conversion can improve efficiency. It adds that low-voltage cable losses offset some of that, and could exceed 15% in poorly designed systems.
Can 120V recessed lights be converted to 48V?
Usually only by replacing the fixtures and running new cable to a rack. Have a licensed electrician make the old 120V wiring safe.
Do 48V lights work in a power outage?
Only if the rack, processor and controls have backup power. One rack means fewer places to back up. Smoke alarms still need their own batteries.
Sources
- Electrical License Renewal, Article 411: 2014 and 2017 NEC text.
- Mike Holt in EC&M, Class 2 circuits, 2020: source, marking, cable, separation.
- Buildings, Class 2 and Class 4, 2025: limits.
- Electrical Contractor, 2023: Class 4 in dwellings.
- 2026 NEC: Electrical Contractor, Chapters 5 to 8. Editions: state adoption list.
- IAEI, Residential lighting under the NEC, 2025: wall controls.
- Canada: IAEI, Section 16, 2018.
- US Department of Energy: PoE cable losses, 2018, hammer test, 2014 and flicker basics.
- US Fire Administration: hardwired smoke alarms.