Wellness Lighting · Dirty electricity
Dirty electricity and LED lights: what causes it and how to test for it
Short answerDirty electricity is high-frequency voltage noise on a building's 60 Hz wiring. LED drivers and dimmers can add to it, and the amount differs widely from one product to the next. The noise can be measured. Whether it affects health is disputed. The practical step is to test products before you choose them.
What is dirty electricity?
Power in a North American home alternates 60 times a second, or 60 Hz. Some devices put faster voltage changes on the same wires. Engineers call this electromagnetic interference, or EMI. Building biologists, who assess homes for environmental factors, call it dirty electricity.
Lighting is one source among several. Oram Miller, a certified building biology consultant, also lists solar inverters, pool pump motors and energy-efficient furnace motors.
What causes dirty electricity in lighting
The LED driver
A driver turns 120V into the low voltage an LED needs. Many do this by switching very quickly. A 2026 study of 18 lamp models found large differences by design, with many LED drivers peaking around 51 to 65 kHz and 74 to 82 kHz.
The dimmer
The amateur radio association ARRL tried one LED dimmer with several bulbs. No combination had a completely acceptable noise level, and in some cases a radio picked up strong noise through the whole house. ARRL noted that other dimmers may be quieter.
The house wiring
At lower radio frequencies a bulb is too small to radiate well. ARRL explains that the bulb passes the noise to the power cord or house wiring, and the wiring then acts as the antenna.
Do all LED lights make dirty electricity?
Not to the same degree. The same 2026 study found high emissions from some low-cost lamps, including lamps from established brands, and well-controlled emissions from others. The Building Biology Institute agrees that quality varies a lot, and says a high-quality LED can be a good choice if it is tested first.
How to measure dirty electricity from lighting
| Tool | What it reads | What to keep in mind |
|---|---|---|
| Plug-in meter, Graham-Stetzer (GS) units | One number for fast voltage changes at an outlet, roughly 10 to 100 kHz | Useful for before and after on one circuit. The scale is not a health limit |
| Plug-in EMI meter | One number on a different scale | Don't compare one meter type's number with the other's |
| Oscilloscope | The shape of the voltage over time | Little published data links its readings to GS units |
| Laboratory network and spectrum analyzer | Noise at each frequency, for example 9 to 150 kHz | The method used in the 18-lamp study |
The on and off baseline test
Miller publishes a simple test for plug-in lamps:
- Plug the lamp and the meter into the same extension cord.Leave the lamp off.
- Write down the baseline.This is the noise already on the circuit.
- Turn the lamp on and read again.A rise points to the lamp. Repeat it to be sure. No rise means the lamp adds nothing this meter can see.
- Test dimmers the same way.An electrician wires the dimmer to an incandescent bulb and an outlet, so the dimmer is the only new source.
Read at full brightness and at low dim levels. ARRL found that noise changed with the dimmer setting.
Is dirty electricity real?
The noise is real. Radio engineers measure it, and US rules limit it for LED lighting from 150 kHz up. What is disputed is the effect on people.
| Question | Building biology view | Mainstream view |
|---|---|---|
| Can it be measured? | Yes, with plug-in meters on each circuit | Yes, but studies measured it in different ways, so results are hard to compare |
| Is there a safe level? | Some use about 50 GS units as a target | De Vocht and Olsen (2016) found no evidence that 50 GS units is more than arbitrary |
| Does it affect health? | Some consultants link it to symptoms and advise reducing it | The same review concluded that the evidence does not stand up to scientific scrutiny, and called for better studies |
| What about EMF sensitivity? | Some people report symptoms and reduce their exposure | A 2005 World Health Organization fact sheet says the symptoms are real, but there is no scientific basis to link them to EMF exposure |
You don't have to settle that debate to ask for a quieter product.
What to ask any lighting maker
Ask every maker you compare.
- Where is the driver? In every fixture, above the ceiling, or in one equipment location?
- What dims the light? A wall dimmer on the 120V circuit, or the driver itself?
- Do you have conducted emissions data? Ask for the report, the frequency range and the model tested.
- Does the data reach below 150 kHz? The US conducted limits that ARRL lists for LED lighting start at 150 kHz, so a pass does not describe 9 to 150 kHz.
- Was it tested with the dimmer, at low levels? Full brightness is only part of the answer.
- What was the baseline? Ask for the off reading next to the on reading, with the meter named.
- How many fixtures were running, and who did the test? One lamp on a bench is not a house.
- Can our consultant test a sample before we commit?
How to reduce dirty electricity from lighting
- Measure first.A baseline shows whether lighting is a source in this house.
- Start with the sources.Miller advises removing or replacing them first.
- Look closely at dimmers.The Building Biology Institute says dimmers generally produce high levels and that using none is the lowest option. It describes constant current reduction dimmers, matched to the right LEDs, as low.
- Decide early where drivers go.It is easy on a drawing and hard after the walls are closed. See the low EMF home lighting plan.
What a central low-voltage system changes
In a Colorbeam system, high voltage enters once, at a central rack, and stops there. The drivers sit in the rack. Downlights are fed at 48V over CAT6 and tape light at 24V over multi-conductor wire.
| Conventional lighting | Colorbeam low-voltage system | |
|---|---|---|
| Where the power electronics sit | Dimmers on the walls, drivers at the fixtures | Together in a central rack |
| 120V lighting cable | From the panel to every switch, dimmer and fixture | Stops at the rack |
| Where to take readings | At many dimmers and fixtures, on many circuits | At the rack and its circuit, then in the rooms |
| Distance from people | Set by where each fixture and dimmer has to be | The rack location is chosen on the plan |
This reduces EMF from the lighting wiring, with the lowest measurable EMF readings in the architectural lighting industry. More on low EMF lighting and how a 48V system works.
What others report
Miller's lighting page lists Colorbeam as "High-end low dirty electricity EMFs and low flicker integrated central lighting solutions". He attributes the testing to another building biologist, Brian Johnson. Johnson's firm, SENERGY360, says it tested Colorbeam itself, for flicker and for electric and magnetic fields around the fixtures and wiring, before specifying it. Colorbeam is its preferred lighting system.
What it doesn't change
- The rack holds power electronics on a 120V circuit. Include that circuit in any test.
- Other sources in the house, and noise that arrives on the utility supply, stay as they are.
Questions and answers
What causes dirty electricity in a house?
Devices that convert or switch power quickly, such as some LED and compact fluorescent lamps, dimmers, power converters and solar inverters. Some noise also arrives from outside the house.
Do LED lights cause dirty electricity?
Some add a lot and some add very little. Published tests show large differences between models, so test the one you plan to use.
Does a dimmer switch cause dirty electricity?
It can. Miller reports about 144 to 198 GS units for a dimmer he considers relatively low and up to 440 to 660 for others. The level depends on the dimmer and the lamp.
Is dirty electricity real or a myth?
The voltage noise is real and measurable. The health claims are disputed, and a 2016 review of 25 publications found that the evidence does not stand up to scientific scrutiny.
Is dirty electricity the same as EMF?
It is one part of the subject. EMF also includes magnetic fields, electric fields and radio frequency, which are measured with different meters. See do LED lights emit EMF.
Where does dimming happen in a Colorbeam system?
At the drivers in the central rack, not at a dimmer behind each wall plate. A keypad or the home control system sends the instruction. Dimming is flicker free, down to 0.1%.
Sources
- Building Biology Institute, Electric light: LED variation, dimmers, testing.
- De Vocht and Olsen, Frontiers in Public Health, 2016: review of the evidence, meters, 50 GS units.
- World Health Organization, Electromagnetic hypersensitivity, 2005: symptoms and evidence.
- Fioravanti et al., 2026 (abstract): 18 lamp models, 9 to 150 kHz.
- ARRL, Light Bulbs and RFI, 2013: bulb and dimmer noise, wiring as antenna, US limits.
- Healthy Building Science, EMI and LEDs, 2013: EMI sources, two meter types, incandescent baseline.
- Create Healthy Homes (Oram Miller), Lighting: other sources, baseline test, dimmer readings, Colorbeam listing.
- SENERGY360, Colorbeam: its own testing.
Comparing lighting for a low EMF home?
Bring the checklist and your drawings.