Wellness · Light biology

Melanopic lighting for home: what it is and how to plan it

Short answerMelanopic light is light weighted by how strongly it stimulates melanopsin, a light-sensitive pigment in the eye that helps set the body clock. It is measured at eye level as melanopic EDI, in lux. Published guidance asks for high values by day, low values before bed and almost none during sleep.

Light biology in plain words

Light biology, also called lighting biology, looks at what light does in the body besides helping us see. The eye has rods and cones for vision. It also has a small group of cells called ipRGCs, short for intrinsically photosensitive retinal ganglion cells.

These cells contain a pigment called melanopsin. It responds most to blue-cyan light, with a peak near 480 nanometers, and near 490 once filtering inside the eye is taken into account. The cells are thought to carry most of the light signal that sets the 24-hour body clock. Rods and cones can contribute too, so melanopsin is the main part of the story but not all of it.

Biological lighting, human centric lighting and circadian lighting are industry names for lighting planned with this in mind. The international lighting commission, the CIE, uses a different term: integrative lighting.

Melanopic EDI, melanopic lux and the other numbers

The method comes from an international standard, CIE S 026:2018.

TermWhat it tells youWhat it does not tell you
LuxHow much light reaches a surface, weighted for human visionHow strongly that light stimulates melanopsin
Color temperature (CCT)How warm or cool white light looks, in kelvinThe melanopic value. Different spectra can share one color temperature
Melanopic EDIThe lux of standard daylight (D65) that would stimulate melanopsin equallyHow one particular person will respond
Melanopic DERThe ratio between melanopic EDI and ordinary lux for one light source, compared with standard daylight (D65)How much light actually reaches the eye
Equivalent melanopic lux (EML)An older unit, often shortened to melanopic lux. Divide it by 1.103 to get melanopic EDI. Check which one a product sheet usesIt is not an SI unit, and it is a different number from melanopic EDI

Circadian light vs color temperature

Color temperature is only a rough guide. Cooler white light often has more melanopic content, but two lights with the same color temperature and the same lux can give quite different melanopic values.

A 2022 study modeled a five-channel LED system at 300 lux. At 3500K, with a color fidelity score of 80 or more, melanopic EDI ran from 157 to 226 lux depending on the spectrum. The authors concluded that color temperature should not stand in for biological potency. The UK's Society of Light and Lighting reports that the CIE also cautions against using it to label a light source healthy or unhealthy.

The result depends on the spectrum, the amount of light at the eye, the timing and the duration. Dimming changes the number as much as color does. Halve the light at the same spectrum and the melanopic EDI halves too.

Published recommendations by time of day

The most used values come from a 2022 paper in PLOS Biology by Brown and colleagues. They apply to healthy adults aged 18 to 55 with regular daytime schedules. The last column is what the light in a Colorbeam home can be set to, which is a setting and not a melanopic result.

Time of dayPublished guidance, at the eyeAt homeWhat the light can do
Morning and daytimeAt least 250 lux melanopic EDIDaylight first. Sit near windows and go outdoorsTune toward 5000K at higher brightness where daylight falls short
Late afternoonDaytime value until the evening period startsKeep blinds open while there is daylightMove from cool to warm on a schedule
Evening, from at least 3 hours before bedNo more than 10 lux melanopic EDIFewer lights on, at lower levelsTune down to 2200K and dim
Getting up at nightNo more than 10 lux melanopic EDI, only where you need to seeLight the path, not the roomSingle fixtures at 2200K, dimmed flicker free to 0.1%
SleepAs dark as possible, no more than 1 lux melanopic EDIClose shades, turn off displaysOff

The paper asks for daylight first, and it puts visual safety ahead of these values where they conflict. A stair must still be lit well enough to use.

Feature L03 of the WELL Building Standard sets values for workstations. A 2023 US Department of Energy report lists the late 2021 version (WELL v2, 2021 Q4) as 136 lux melanopic EDI (150 EML) for one point and 250 lux (275 EML) for three. WELL has changed these numbers over time, so check the current edition.

Measured at the eye, not on the table

Lighting plans usually count light on a horizontal surface, such as a counter. Melanopic EDI is taken on a vertical plane at eye level, about 1.2 m (4 ft) from the floor for a seated person, facing the way that person looks.

A seat facing a window and a seat facing a dark wall in the same room receive very different light.

What a tunable system can and cannot do

QuestionIt canIt cannot
DaytimeAdd cooler, brighter light where a room lacks daylightReplace outdoor light. Direct sun reaches up to 100,000 lux; standard office lighting is around 500 lux, often lower
EveningLower the level and warm the color togetherChange the light from screens, windows and lamps outside the system
NightLight one fixture at a very low level, flicker freeMake a room darker than its shades allow
ScheduleRun scenes by time of day, room by roomKnow your own sensitivity. In one study it varied more than tenfold between people

The Society of Light and Lighting says no product is circadian by itself: what counts is the pattern of light a person receives. In a Colorbeam home, every fixture is individually addressable, tunes from 2200K to 5000K and dims flicker free to 0.1%. Scenes and schedules are stored on the GATEway processor. More on circadian lighting and flicker-free dimming.

How to plan day, evening and night at home

  1. List where people sit, and when.Breakfast table, desk, sofa, bed. Note the view direction and the hours.
  2. Plan daylight first.Put daytime seats near windows and manage glare with shades.
  3. Add daytime electric light where it is short.Look at light on walls and at the eye, not only on the counter.
  4. Give evenings their own layer.Low, warm light for at least 3 hours before bed, with bright task light only where it is needed.
  5. Plan the night path.Bed to bathroom, stairs and hall, at the lowest safe level.
  6. Ask for data, then check.If your brief has a melanopic target, ask the manufacturer for spectral data at the settings you will use. After installation, measure at eye level and adjust the scenes.

A lighting design study can set positions and scenes. Related guides: healthy home lighting and building biology lighting.

Questions and answers

What is melanopic EDI?

Melanopic equivalent daylight illuminance: the amount of standard daylight, in lux, that would stimulate melanopsin as much as the light being measured.

How much melanopic light is recommended?

For healthy adults aged 18 to 55 with regular daytime schedules, Brown and colleagues (2022) recommend at least 250 lux melanopic EDI at the eye through the day, no more than 10 lux from at least 3 hours before bed, and no more than 1 lux during sleep.

Does 5000K light mean enough melanopic light?

No. The value also depends on the spectrum and on how much light reaches the eye. In one simulation at 300 lux and 5000K, melanopic EDI ranged from 196 to 319 lux across different spectra.

Is warm light free of melanopic content?

No, but it can be low. The 2022 paper notes that many warm white home LEDs (2700K to 3000K) can meet the 10 lux evening value at about 30 lux of ordinary light. Level matters as well as color.

What is human centric lighting, explained simply?

Lighting planned around both what people see and how light acts on the body through the day. It is a design approach, not a product feature. Melanopic EDI is one of the numbers used to plan it.

How do you measure melanopic EDI?

Measure the spectrum at eye level, facing the normal view, then run the calculation. The CIE offers a toolbox for it. A lux reading alone is not enough, because it does not include the spectrum.

Sources

Planning light through the day?

Talk through the rooms, the daylight and the scenes before the plan is fixed.