Wellness Lighting · Building Biology
Building biology lighting: what it asks for and how to specify it
Short answerBuilding biology lighting keeps electric and magnetic fields low, avoids flicker and dirty electricity, uses wired controls, and follows daylight: cooler by day, warm and dim in the evening. Building biologists check it with meters. Colorbeam is designed around the same points, with low-voltage wiring, flicker free dimming and tunable light.
What building biology is
Building biology is about healthy, sustainable buildings. It uses nature as the standard and works by precaution. This page draws on two institutes: the Institute of Building Biology + Sustainability (IBN) and the Building Biology Institute.
Each publishes 25 principles. IBN's light principle asks for plenty of daylight, plus flicker-free light sources and color schemes that come close to natural light. Another asks to minimize electromagnetic fields and wireless radiation. The Building Biology Institute's version asks for ample, well-balanced natural light and illumination, and for strategies that limit exposure from building electrification and from wireless devices.
Testing follows the Standard of Building Biology Testing Methods, known as SBM. The current edition, SBM-2024, is published by Baubiologie Maes and IBN. Light is one of its standard points. It covers spectrum, flicker, light level, color rendering, color temperature and the fields around the lights.
Building biologist recommended lighting: what they look at
The middle column is drawn from the documents listed under Sources. The SBM-2024 field values are precautionary targets for sleeping areas, far below public exposure guidelines: 20 nT for AC magnetic fields, against an ICNIRP 2010 public reference level of 200,000 nT at 60 Hz.
| What building biology looks at | What to ask for | How Colorbeam is designed for it |
|---|---|---|
| AC electric fields | At the bed, below 1 V/m with ground reference or 0.3 V/m without (SBM-2024 "no anomaly"). Keep 120V wiring away from where people sleep | High voltage stops at a central rack. 48V over CAT6 to downlights, 24V to tape light. Measure on site |
| AC magnetic fields | At the bed, below 20 nT or 0.2 mG (SBM-2024 "no anomaly"), checked with the lights on | Power and drivers sit in the rack, which can be placed away from bedrooms. Measure on site, at full output |
| Fields at the light itself | At 30 cm, up to 2 kHz: below 10 V/m and 50 nT. Above 2 kHz: below 1 V/m and 5 nT (SBM-2024) | Low-voltage fixtures, with drivers in the rack. Measure on site, at each fixture type in use |
| Dirty electricity | The Building Biology Institute says dimmers generally add it, and that LEDs should be tested for it before use. SBM-2024 rates about 2 kHz to 1 MHz more strictly | No 120V wall dimmer in the lighting run. Drivers are together in the rack. Measure on site, at the rack circuit and at bedroom outlets |
| Flicker | Flicker percentage ideally about or below 1 or 2 percent, especially up to about 3,000 Hz (SBM-2024) | Flicker free, dims to 0.1%. Record the waveform on site at the dim levels in use |
| Color through the day | About 4000 to 6000K by day and 1500 to 3000K in the evening (SBM-2024) | Tunable from 2200K to 5000K. Scenes and schedules are stored on the GATEway processor |
| Spectrum | Continuous, with smooth transitions and no large blue spike. SBM-2024 also asks for high near infrared | HEKA chipset: added cyan and enhanced red, no violet or UV. Near infrared: ask for the spectral data of the selected fixture |
| Color rendering | CRI above 95 (SBM-2024) | R9 of 97 with the HEKA chipset. Ask for the CRI of the selected fixture |
| Wireless controls | Wired. The Building Biology Institute does not recommend wirelessly controlled lighting | Wired from rack to fixtures. Keypads and the home control system are chosen separately: specify wired ones |
| Darkness at night | As dark as possible where people sleep, ideally 0 lux and below 1 lux at night (SBM-2024) | Each fixture is individually addressable, so lights can be set one by one. Window light and other devices are a separate job |
Best lighting for healthy homes: what the fact sheet says about lamps
The Building Biology Institute's electric light fact sheet compares lamp types. It rates incandescent lamps well on fields and spectrum and poorly on energy use. It does not recommend fluorescent lamps. It says LEDs vary a great deal in quality, and that a high-quality LED can be a good choice if its dirty electricity is tested first.
Where Colorbeam fits
Low EMF wiring
High voltage enters once, at the rack, and stops there. This reduces EMF from the lighting wiring. The result is the lowest measurable EMF readings in the architectural lighting industry.
Low EMF lightingStable light
Dimming is flicker free at every level, down to 0.1%, with the drivers in the rack and no 120V dimmer on the wall.
Flicker-free dimmingDirty electricity and LEDs
Light that follows the day
Cooler light by day and 2200K in the evening, on a schedule, with each fixture set on its own.
Circadian lightingMelanopic light
Tested by a building biologist's firm
SENERGY360 is a healthy-home design firm founded by Brian Johnson, a certified building biologist. The firm says it tested Colorbeam itself, looking at flicker and at the electric and magnetic fields around the fixtures and their wiring. It calls Colorbeam its preferred lighting, "chosen after SENERGY360's own testing". It designs the system with shielded CAT6 runs back to a central location. Colorbeam is also listed in the Healthy Building Alliance directory.
How to specify lighting for a client who is sensitive to EMF
Agree on what will be measured first, then design to it.
- Write down the targets.Ask the client's building biologist which values apply, in which rooms and at which positions. SBM-2024 is one starting point for bedrooms.
- Take a baseline.Measure before the lighting goes in, so other sources can be told apart.
- Plan the rack location.The rack is where high voltage and drivers sit. Keep it away from beds, and check the floors above and below. Field levels fall quickly with distance.
- Keep 120V lighting wiring out of the rooms.Run low voltage from the rack to each light. Have a licensed electrician confirm what code requires for lighting, switches and other circuits.
- Decide on shielding.If shielded cable is wanted, put the cable and its grounding in the drawings, checked by a licensed electrician. The Building Biology Institute lists shielded and twisted cables, layout, earthing and cut-off switches as parts of a low-field wiring design.
- Ask for wired controls.List every keypad, processor, bridge and sensor, and mark any that use radio.
- Set the evening scenes.Low level, 2200K, and dark in the bedroom overnight.
- Measure before handover.Lights off, full output and the dim levels the client will use, at the bed and the usual seats.
- Keep the record.Write down the meter, its frequency range, the positions and the scene. Repeat after any change.
The room-by-room version is in the low EMF home lighting plan. Test conditions for consultants are on the wellness professionals page. See also do LED lights emit EMF.
What is measured and what is disputed
Fields, flicker and spectrum can be measured. WHO explains that electric fields come from voltage and are there even when no current flows, while magnetic fields come from current. What those fields mean for health at household levels is disputed. WHO says current evidence does not confirm health consequences from low-level fields. Its 2005 backgrounder on electromagnetic hypersensitivity says the symptoms are real and that there is no scientific basis to link them to EMF exposure. The Building Biology Institute reads the early studies on dirty electricity as a reason for precaution and more research.
Questions and answers
What lighting do building biologists recommend?
The published documents describe qualities more than products: daylight first, low electric and magnetic fields, low dirty electricity, no flicker, wired controls, and color that is cooler by day and warm in the evening. SENERGY360, founded by a certified building biologist, names Colorbeam as its preferred lighting system after its own testing.
Is Colorbeam approved by the Building Biology Institute?
Colorbeam does not claim certification or endorsement by the Building Biology Institute or IBN. The preference quoted here is SENERGY360's own.
Are LEDs acceptable in a building biology home?
Yes, with testing. The Institute's fact sheet says high-quality LEDs can be a good choice as long as dirty electricity is tested before use.
Are dimmers a problem in building biology?
The Institute says dimmers generally produce high dirty electricity, with an exception for some constant current reduction dimmers matched to their LEDs. Colorbeam has no 120V wall dimmer in the lighting run: the drivers sit in the rack.
Does low-voltage lighting remove all EMF from a home?
No. It reduces EMF from the lighting wiring. Outlets, appliances and outside sources stay as they are.
Is smart lighting compatible with building biology?
The Institute does not recommend wirelessly controlled lighting. Scenes and schedules do not have to be wireless. In a Colorbeam system they are stored on the GATEway processor and the fixtures are wired to the rack. Choose wired keypads to match.
Sources
- IBN, The 25 guiding principles of building biology
- Building Biology Institute, 25 principles
- Baubiologie Maes and IBN, Standard of Building Biology Testing Methods SBM-2024, with the evaluation guidelines and testing conditions
- Building Biology Institute, Electric light fact sheet
- Building Biology Institute, Dirty electricity fact sheet
- Building Biology Institute, Electrical home wiring fact sheet
- ICNIRP, Guidelines for 1 Hz to 100 kHz (2010)
- WHO, Electromagnetic fields: questions and answers
- WHO, Electromagnetic hypersensitivity backgrounder (2005)
- SENERGY360, Colorbeam: the lighting system we prefer
Planning lighting for a building biology project?
Bring your targets, drawings and test plan to the first call.